DentistryEndodonticsEndodontic InstrumentationRoot Canal TherapySurgical EndodonticsApical PreparationCone Beam Computed Tomography InterpretationRoot Canal AnatomyRoot Canal Anatomy ImagingRoot Canal ObturationCanal Curvature AssessmentCanal Preparation InstrumentsCanalsRadiographic Root Canal AssessmentRoot Canal Curvature AnalysisRoot Canal Curvature MeasurementThree-dimensional Root Canal Imaging
INTRODUCTION: Due to the importance of apical transportation during root canal preparation, the aim of the current study was to use cone-beam computed tomography (CBCT) to assess the extent of apical transportation caused by ProTaper and Mtwo files. METHODS AND MATERIALS: Forty extracted maxillary first molars with 19-22 mm length and 20-40 degrees of curvature were selected. The mesiobuccal canals were prepared using either Mtwo or ProTaper rotary files (n=20). CBCT images were obtained before and after canal preparation to compare the apical transportation in different cross-sections of mesial and distal surfaces. The apical transportation values were analyzed using the SPSS software. The results were compared with student's t-test and Mann-Whitney U test. RESULTS: There was no significant difference in the extent of apical transportation between Mtwo and ProTaper systems in different canal cross-sections. The apical transportation value was less than 0.1 mm in most of the specimens, which was clinically acceptable. CONCLUSION: Considering the insignificant difference between the two systems, it can be concluded that both system have low rates of apical transportation and can be assuredly used in clinical settings.
22
Cleaning and Shaping the Root Canal
Herbert Schilder · Dental Clinics of North America · 1974 · 1.4K citations