Publication | Closed Access
Noninvasive investigations of the normal ocular circulation in humans.
114
Citations
35
References
1998
Year
The reproducibility of fundus pulsation measurements was excellent. Reproducibility of pneumatonometric parameters and ultrasonographic measurements in the OA was satisfactory. Reproducibility of ultrasonographic measurements in the PCAs was low. Data obtained during the autonomic stimuli experiments argue against the sole use of systems to measure pulsatile blood flow, if no additional data on flow pulsatility are available. At least in cases when changes in blood pressure are likely to occur the ratio of pulsatile to nonpulsatile blood flow might not be constant and POBF might not be an adequate measure of total ocular blood flow.