Journal of Bone and Joint Surgery · 2003 · 140 citations · 17 references
MedicineOrthopedic SurgerySurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsBone BiomechanicsBone MechanicsShear PropertiesBone Graft MechanicsFresh-frozen Osteochondral AllograftsImpaction Bone GraftingInterparticle FrictionMorselized Bone GraftShear MechanicsShear ResistanceShear Testing
Background: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. Methods: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). Results: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. Conclusions: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required. Clinical Relevance: Understanding the mechanical properties of milled human allograft is important when impaction grafting is used for mechanical support. A simple means of improving the mechanical strength of graft produced by currently available bone mills, including an intraoperative washing technique, is described.
17
Bone grafting in total hip replacement for acetabular protrusion
Tom J.J.H. Slooff, R. Huiskes, Jim van Horn et al. · Acta Orthopaedica Scandinavica · 1984 · 429 citations · Full text
Massive early subsidence following femoral impaction grafting
Jonathan Eldridge, Evert J. Smith, M. J. W. Hubble et al. · The Journal of Arthroplasty · 1997 · 252 citations
Hans Burchardt, W F Enneking · Surgical Clinics of North America · 1978 · 189 citations