2015 · 11 citations · 11 references
EngineeringElectrical EngineeringPhysicsProcess ControlUltrasoundVibrationTransducer TechnologyTransient VibrationUltrasonicsUltrasound InstrumentationUltrasound PhysicsVibration ControlAmplitude Of VibrationMechanical TransducersRelative PhaseSmall-amplitude VibrationTransducer SimulationUltrasonic TransducersVoltage
The control of the vibration amplitude, and the resonance frequency tracking for ultrasonic transducer have been established. However, some applications require to control the vibration amplitude and its relative phase at a fixed frequency as the generation of travelling wave. In this paper, the transducer is modelled in rotating frame, and the decoupling according to two-axis allows to obtain a double independent closed loop control to address this issue. It is possible to control the transducer vibration amplitude and its relative phase, in steady state even in transient by acting on the amplitude of the supply voltage. Thanks to vector control method. This approach will be confirmed with experimental and simulation results.
11
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Kullervo Hynynen, Nathan McDannold, Natalia Vykhodtseva et al. · Radiology · 2001 · 1.5K citations