Clinical Oral Implants Research · 2011 · 61 citations · 25 references
DentistryOrthopedic SurgerySurgeryImplant ProsthodonticsImplant SurgeryProstheticsImplant Prosthetic MaterialsScrew-retained ProsthesesScrew-retained RestorationsAbutment Screw LooseningAbutment Screw TorqueImplant-abutment InterfaceMechanical LoadingProsthetic Screw TorqueRemoval TorqueTorqueTorque-based Removal
OBJECTIVES: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. MATERIAL AND METHODS: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: (1) abutments without hexagon at the base and (2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. RESULTS: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that (1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, (2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and (3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.
25
Implants and components: entering the new millennium.
Paul P. Binon · PubMed · 2000 · 474 citations
Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study.
Peter J. Henry, William R. Laney, Torsten Jemt et al. · PubMed · 1996 · 461 citations
Elongation and preload stress in dental implant abutment screws.
James E. Haack, Ronald L. Sakaguchi, Ting Sun et al. · PubMed · 1995 · 319 citations
Dentistry, Implant Dentistry, Mechanical Behavior Of Materials +12
The effect of implant/abutment hexagonal misfit on screw joint stability.