BMC Medical Imaging · 2006 · 12 citations · 21 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyHepatobiliary ImagingImage RegistrationLiver ImagingMagnetic Resonance ImagingMedical ImagingDynamic ImagingLiver Volume AssessmentMagnetic Resonance PhysicsMultiresolution AnalysisNon-rigid Volume RegistrationRigid Image RegistrationRigid RegistrationRigid Volume Registration
BACKGROUND: Subtraction of Dynamic Contrast-Enhanced 3D Magnetic Resonance (DCE-MR) volumes can result in images that depict and accurately characterize a variety of liver lesions. However, the diagnostic utility of subtraction images depends on the extent of co-registration between non-enhanced and enhanced volumes. Movement of liver structures during acquisition must be corrected prior to subtraction. Currently available methods are computer intensive. We report a new method for the dynamic subtraction of MR liver images that does not require excessive computer time. METHODS: Nineteen consecutive patients (median age 45 years; range 37-67) were evaluated by VIBE T1-weighted sequences (TR 5.2 ms, TE 2.6 ms, flip angle 20 degrees , slice thickness 1.5 mm) acquired before and 45s after contrast injection. Acquisition parameters were optimized for best portal system enhancement. Pre and post-contrast liver volumes were realigned using our 3D registration method which combines: (a) rigid 3D translation using maximization of normalized mutual information (NMI), and (b) fast 2D non-rigid registration which employs a complex discrete wavelet transform algorithm to maximize pixel phase correlation and perform multiresolution analysis. Registration performance was assessed quantitatively by NMI. RESULTS: The new registration procedure was able to realign liver structures in all 19 patients. NMI increased by about 8% after rigid registration (native vs. rigid registration 0.073 +/- 0.031 vs. 0.078 +/- 0.031, n.s., paired t-test) and by a further 23% (0.096 +/- 0.035 vs. 0.078 +/- 0.031, p < 0.001, paired t-test) after non-rigid realignment. The overall average NMI increase was 31%. CONCLUSION: This new method for realigning dynamic contrast-enhanced 3D MR volumes of liver leads to subtraction images that enhance diagnostic possibilities for liver lesions.
21
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Neil M. Rofsky, Vivian S. Lee, Gerhard Laub et al. · Radiology · 1999 · 536 citations
Albert Macovski · Magnetic Resonance in Medicine · 1996 · 414 citations