U.S. Geological Survey circular/U.S. Geological Survey Circular · 1969 · 23 citations · 4 references
ManagementEnvironmental EngineeringEnvironmental ManagementSolid Waste ManagementSubsurface Fluid FlowWaste ManagementDisposal FacilitiesWaste CharacterizationWaste DisposalWaste Disposal StandardsIndustrial Liquid Waste ManagementInjection DepthInjection PressureInjection Waste DisposalInjection Waste ManagementUnderground DisposalUnderground InfrastructureUnderground Spaces
Injecting liquid wastes deep underground is an attractive but not necessarily practical means for disposing of them. For decades, impressive volumes of unwanted oil-field brine have been injected, currently about 10,000 acre-feet yearly. Recently, liquid industrial wastes are being injected in ever-increasing quantity. Dimensions of industrial injection wells range widely but the approximate medians are: depth, 2,660 feet; thickness of injection zone, 185 feet; injection rate, 135 gallons per minute; wellhead injection pressure, 185 pounds per square inch.
4