PubMed · 2004 · 16 citations · 22 references
MedicineClinical SciencesRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic RadiologyChest RadiographyChest RadiologyComputed TomographyPulmonary ImagingPulmonary Nodule EvaluationThoracic RadiographyDifferential Diagnosis CriteriaGross Differential DiagnosisMultidetector Computed TomographyPulmonary Nodule DiagnosisPulmonary Nodule LocalizationSolitary Pulmonary Nodule AssessmentSolitary Pulmonary Nodule CharacterizationThoracic Imaging Differential Diagnosis
PURPOSE: The purpose of this study was to evaluate the usefulness of the coronal multiplanar reconstruction (MPR) view in comparison with transverse helical thin-section CT for both the determination of malignant or benign lesions and the differential diagnosis of solitary pulmonary nodules. MATERIALS AND METHODS: Sixty-eight cases of pathologically proved solitary pulmonary nodule less than 3 cm in diameter were enrolled in this study. For the routine study, transverse helical thin-section CT (1.25 mm collimation, FOV 20 cm) covering the areas with solitary pulmonary nodules as well as whole lung helical thin-section CT (2.5 mm collimation, 1.25 mm reconstruction interval, FOV 34.5 cm, pitch 6:1, high-spatial frequency algorithm) were scanned with a multidetector-row CT (MDCT) scanner. From the whole lung thin-section CT data, coronal MPR views (2.5 mm slice thickness) were reconstructed on a workstation. ROC analysis was used for an observer performance study, in which three observers indicated their confidence level for the determination of malignant or benign lesion for the nodules by means of transverse thin-section CT and coronal MPR. In addition, the observers recorded appropriate disease entities as the final diagnosis of each case. Accuracies of the final diagnosis based on the two sets of images were compared with McNemer' s test. RESULTS: In terms of the determination of malignant or benign lesion, there was no significant difference between the two sets of images (coronal MPR and transverse thin-section CT; mean Az=0.853 and 0.854, respectively). In addition, accuracy of the final diagnosis based on coronal MPR views (74%) was almost equal to that based on transverse thin-section CT (71%) (p=0.3). CONCLUSIONS: The diagnostic efficacy of the coronal MPR view is comparable to that of transverse thin-section CT for the evaluation of solitary pulmonary nodules.
22
Solitary pulmonary nodule: high-resolution CT and radiologic-pathologic correlation.
Charles Zwirewich, Sverre Vedal, Roberta R. Miller et al. · Radiology · 1991 · 532 citations
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hui Hu, Hairong He, W. Dennis Foley et al. · Radiology · 2000 · 511 citations
Multi‐slice helical CT: Scan and reconstruction
Hui Hu · Medical Physics · 1999 · 496 citations