Feedwater repowering of 800 MW supercritical steam power plant

29

Citations

1

References

2012

Year

Abstract

The paper presents concept of using hot exhaust gases from the gas turbine to heat up feedwater in supercritical power plant unit. The benefits of such solution are discussed and the factors to be taken into account are listed. Details are discussed criteria to be met by gas turbine, in order to be safely and optimally connected to the steam system. Reference unit model with 800 MW electric power was created, which was later supplemented with a gas turbine. The system with gas turbine in relation to “clean” steam system has greater power and efficiency. The power increase is due to the extra power generated by gas turbine and steam system higher output by increasing amount of steam flow through the turbine (closed extraction to bypassed high-pressure heat exchanger).