Journal of Refractive Surgery · 1992 · 47 citations · 15 references
MedicineOphthalmologySurgeryBiomechanicsFinite Element AnalysisFinite Element MethodsCorneal AnatomyCorneal BiomechanicsCorneal PhysiologyElasticity TheorySolid Mechanics ApplicationsStress AnalysisAnterior Corneal BiomechanicsCorneal Biomechanics ModelingCorneal Tissue MechanicsFlexibilityIntraocular Pressure Effects On Corneal MechanicsLarge Deformation MechanicsLarge Deformation ModelingMechanical Modeling
BACKGROUND: In this article, we examine the finite element method and its use in mechanical modeling of the cornea. METHODS: Both linear elastic and geometrically nonlinear models are considered. The effects of corneal geometry, boundary conditions, thickness, and the number of layers in the model are determined. RESULTS: Results indicate that, for intraocular pressure loading, the thickness and the choice of boundary conditions at the limbus are significant. CONCLUSIONS: A model of tonometry showed that simulating the layered nature of the cornea and including the increased flexibility of large deformation are critical.
15
Nonlinear material properties of intact cornea and sclera
Savio L‐Y. Woo, A. S. Kobayashi, William A. Schlegel et al. · Experimental Eye Research · 1972 · 319 citations
The mechanical properties of the rabbit and human cornea
Bill Jue, David M. Maurice · Journal of Biomechanics · 1986 · 221 citations
Rheology of the cornea: Experimental techniques and results
Gerald W. Nyquist · Experimental Eye Research · 1968 · 100 citations