Comparison of three vascular endothelial markers in the evaluation of microvessel density in breast cancer.

B. B. Da Silva, Vítor P. Lopes, Arnaldo Rodrigues Santos, E C de Sousa-Júnior, Airlane Pereira Alencar, CG Pires, M A Rosal

PubMed · 2009 · 27 citations · 0 references

Concepts

Abstract

PURPOSE: To evaluate the microvessel density by comparing the performance of anti-factor VIII-related antigen, anti-CD31 and anti-CD34 monoclonal antibodies in breast cancer. METHODS: Twenty-three postmenopausal women diagnosed with Stage II breast cancer submitted to definitive surgical treatment were evaluated. The monoclonal antibodies used were anti-factor VIII, anti-CD31 and anti-CD34. Microvessels were counted in the areas of highest microvessel density in ten random fields (200 x). The data were analyzed using the Kruskal-Wallis nonparametric test (p < 0.05). RESULTS: Mean microvessel densities with anti-factor VIII, anti-CD31 and anti-CD34 were 4.16 +/- 0.38, 4.09 +/- 0.23 and 6.59 +/- 0.42, respectively. Microvessel density as assessed by anti-CD34 was significantly greater than that detected by anti-CD31 or anti-factor VIII (p < 0.0001). There was no statistically significant difference between anti-CD31 and anti-factor VIII (p = 0.4889). CONCLUSION: The density of stained microvessels was greater and staining was more intense with anti-CD34 compared to anti-CD31 and anti-factor VIII-related antigen.