Vehicle mass emissions measurements using a portable 5-gas exhaust analyzer and engine computer data

Michal Vojtíšek-Lom, J.T. Cobb

2009 · 26 citations · 3 references

Concepts

Abstract

The University of Pittsburgh commuter vanpool operates 20 dedicated compressed natural gas vans. Data on fuel use, maintenance, oil contaminants, and tailpipe emissions on these vans are collected. A method is being developed to determine “real-world” mass emissions using an on-board low-cost fivegas non-dispersive infra-red exhaust gas analyzer, an engine diagnostic scanner and a laptop computer. The computer uses live engine diagnostic port data to compute molar exhaust flow, which, when multiplied by molecular weight and measured concentrations of exhaust gases, yields grams per second data. Grams per mile emissions are calculated from known distance and time of the trip. The $10,000 system, also capable of measuring fuel consumption, is portable, requires no modifications to the vehicle, and uses commercially available instruments. Although the system yields consistent data on an 8-mile test route, values measured during I/M 240 tests show correlations of 0.67 for NOx, 0.50 for HC and 0.68 for CO between the portable and I/M 240 instruments and high test-to-test differences. Others have found good correlation between I/M 240 and portable analyzer mass emission. The poor correlation in this study may be attributed to extremely low emissions (tenths of a percent of the instrument range) of the tested vehicles. Improving the accuracy is the focus of ongoing research.

References

3