Journal of AOAC INTERNATIONAL · 1986 · 36 citations · 0 references
AgricultureChemistryFood ScienceAnalytical ChemistryFood AnalysisFood ChemistryColor ChemistryFood Safety AnalysisAcid DigestionColorimetric TestsDetection Limit AssessmentDetection Limit EstimationFood Safety DetectionIodine ChemistryIodine Value DeterminationMethod Detection Limit
An earlier acid digestion determination of iodine in foods was modified to provide an improved detection limit and to allow for the analysis of a greater variety and larger amounts of foods. The organic material in the sample was oxidized overnight by concentrated nitric acid, followed by digestion in a mixture of concentrated sulfuric and 70% perchloric acid. The iodine was determined by an automated colorimetric method based on the iodide-catalyzed reduction of Ce+4 by As+3. The method had an average relative standard deviation of 3.1% for the samples analyzed, and a detection limit of 0.1 ng/mL in the digested solution and 5 ng/g in a 2 g sample prior to digestion. The recovery of added iodine ranged from 90.3 to 101.3%, using external standards. Samples analyzed included NBS Standard Reference Material 1549, and composites of a variety of dairy products, meat, eggs and fish, cereals, and potatoes. The iodine detected in these samples ranged from 9 ng/g for the potato group to 3360 ng/g for the standard reference material.