1985 · 18 citations · 0 references
EngineeringAutomotive EngineeringCivil EngineeringFire ManagementFire Protection EngineeringHazard IdentificationFire HazardsFire SafetyFire Safety EngineeringFire SimulationFire TestingStructural Fire EngineeringFire ProtectionFire Protection DesignFire Safety TestingFire Weather ConditionsFire-induced Structural FailureFire-safety Performance TestingStructural Fire ProtectionStructural Fire Testing
Two fire tests on an open deck car park constructed of unprotected steelwork were conducted at the BHP Melbourne research laboratories in may 1985. The tests were carried out to determine whether fire protection of steelwork is necessary and whether there is any possibility of collapse of a car park structure due to fires in the car park itself. The car park structure was constructed of steel members representative of the smallest members likely to be used in practice in an open deck car park. For both tests the top level of the car park was loaded to simulate the presence of cars and five cars were placed on the bottom floor and spaced about 400 mm apart. In the first test, only the car in which the fire was started (the test car) was burnt, while in the second test the test car and the cars on each side were burnt. The test structure supported the loads throughout both tests and the measured steel temperatures showed that a significant factor of safety can be associated with unprotected open deck car parks under fire conditions (a).