Relative Changes in Oxyhemoglobin, Deoxyhemoglobin and Intracranial Blood Volume during Surfactant Replacement Therapy in Infants with Respiratory Distress Syndrome

Hubert Fahnenstich, Stefan E. Schmidt, S. Spaniol, Sabina Kowalewski

Developmental Pharmacology and Therapeutics · 2017 · 10 citations · 0 references

Concepts

Abstract

Oxy-, deoxyhemoglobin and total blood volume were studied by near-infrared spectroscopy (NIRS) during surfactant replacement therapy. These parameters were compared with parameters watched during conventional noninvasive monitoring (pulseoximetry, transcutaneous pO2 and pCO2, heart rate). Seven premature infants (28 +/- 3 weeks of gestation, 940 g birth weight) were given surfactant intratracheally. Immediately after surfactant administration, oxyhemoglobin decreased, deoxyhemoglobin and total blood volume increased. The prior status was re-established after 60-220 s and then oxyhemoglobin increased to a very stable maximum. NIRS allows continuous bedside noninvasive monitoring of all parameters.