Publication | Closed Access
Hematology reference values for peripheral blood of laboratory rats.
18
Citations
0
References
1986
Year
ThrombopoiesisThrombosisCobs CdLaboratory HematologyBlood PlateletMedicinePhysiologyHematologyBlood CellPathologyHemostasisCoagulation ParametersReference ValuesClinical ChemistryHematology Reference ValuesLaboratory MedicineAtherosclerosisHealth Sciences
Reference values for peripheral red and white blood cells, platelets and coagulation parameters from 11 and 18-week-old Charles River Sprague Dawley rats [Cr1:COBS CD(SD)] were obtained using automated methods. The Coulter Model S Senior, the Clay Adams Ultra-Flo Platelet Counter and the Sherwood Lancer Coagulyzer, were used to measure these parameters on 25 rats/sex. Detailed information on instrumentation or assay methods, and the animals, their source, environment and blood collection method was given. Platelet counts were in the range of 694 X 10(9)/1 to 1412 X 10(9)/1 which was higher than previously reported. In general, the remaining ranges were similar to previously published reference ranges.