Medical Engineering & Physics · 2000 · 12 citations · 5 references
MedicineSurgeryFinite Element AnalysisFinite Element MethodsSkin GraftingSkin SurgerySkin Tissue EngineeringSuturing Instruments3D Skin ModelsSkin MechanicsSuture Anchor MaterialsSuture Material PropertiesSuture Microarchitecture
Suturing of postoperative wounds in skin unfortunately leads to extrusion of the skin, resulting in so-called "dog ear". We performed three-dimensional finite element method (FEM) analyses to investigate how suture methods affect the height of the extrusion. Three models were prepared: (1) conventional suture method Sp; (2) S-shaped modified suture model Si-1, in which one side of the curves is introverted; and (3) another S-shaped suture model Si-2, in which both sides of the curves are introverted. The results of FEM analysis agreed well with the figure and location of the extrusions in clinical suture surgery and the height of the extrusion was mimicked visually in three dimensions. The height of the extrusion peak of the S-shaped modified suture method Si-1 was decreased by 40% in comparison with the conventional suture method Sp.
5
Optimal patterns for suturing wounds
Hans Chaudhry, Bruce Bukiet, M. Siegel et al. · Journal of Biomechanics · 1998 · 32 citations
Computer-Aided Analysis of Z-Plasties
Hidehiko Kawabata, Hideo Kawai, Kazuhiro Masada et al. · Plastic & Reconstructive Surgery · 1989 · 20 citations