Development of a Wet-based NDIR and Its Application to On-board Emission Measurement System

Hiroshi Nakamura, Nobutaka Kihara, Masayuki Adachi, Kozo Ishida

SAE technical papers on CD-ROM/SAE technical paper series · 2002 · 37 citations · 5 references

Concepts

Abstract

<div class="htmlview paragraph">Due to a need for a robust measurement system for on-board real-world vehicle emission measurement, a heated ND-IR(h-NDIR) technique has been developed and evaluated for its potential. The h-NDIR is capable of measuring CO and CO<sub>2</sub> under wet-based condition by correcting interference from co-existing gas with an algorithm specially developed for the present study. The resulting H<sub>2</sub>O interference to the CO<sub>2</sub> measurement is less than 0.01vol% for zero point and less than ±1% for span points and that of CO measurement is less than 0.001vol% for zero point and less than ±2% for span point against 0 to12vol% H<sub>2</sub>O.</div> <div class="htmlview paragraph">An on-board emission measurement system using the h-NDIR in combination with an Annubar® flow meter and an air to fuel ratio sensor has been evaluated. The result reveal correlation between the present system and a chassis test system to be within 7% for fuel consumption, within 5% for CO mass emission, and within 6% for CO<sub>2</sub> mass emission.</div>

References

5