CO2 Cooling Developments for HEP Detectors

B. Verlaat, Auke Pieter Colijn

2010 · 10 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

Two phase (evaporative) CO 2 detector cooling is gaining significant interest as a demonstrated alternative to traditional cooling techniques in High Energy Physics (HEP). The upgrade programs of the inner detectors of ATLAS and CMS are investigating evaporative CO 2 cooling as an alternative to the current fluorocarbon cooling systems. CO 2 as coolant has superior thermo dynamical properties compared to other coolants used in HEP detectors leading to significant smaller diameter cooling pipes and hence lower mass inside the detector. Two operational HEP detectors use evaporative CO 2 cooling as part of the thermal management of their silicon detectors; the LHCb-VELO and the AMS02-Tracker. Both CO 2 systems use the 2-Phase Accumulator Controlled Loop (2PACL) technique developed at Nikhef. The 2PACL method is an ideal method for HEP detectors as it is very stable, uses only passive components inside the detector volume and it is easy to control. This paper describes the experiences gained with CO 2 cooling in the past and looks at possible future applications within HEP experiments. Special attention is paid to the amount of material needed inside the active detector volume when CO 2 is used.

References

8