PubMed · 2000 · 187 citations · 0 references
MedicineImplant DentistryBone AugmentationBone GraftingTissue EngineeringBone Graft MaterialsBone Graft SubstitutesBone SubstitutesOsteogenesisSinus Floor AugmentationSinus Floor ElevationBone Mineral DensityNew Bone FormationOsteoconductive GraftsOsteoconductive MaterialsPorous Bone SubstitutesSinus FormationSinus Graft MaterialsSurgical Implant Placement
The efficacy of Bio-Oss as a graft material for sinus floor elevation was studied in 15 patients. A total of 20 sinus augmentation procedures was performed, and 6 months later 57 implants were placed into the augmented sinuses. New bone formation was confirmed in biopsies of 3 patients (new bone: 21.08% +/- 7.25% after 6 mo, 27.55% +/- 4.88% after 12 mo; Bio-Oss: 39.17% +/- 4.36% after 6 mo, 27.01% +/- 11.64% after 12 mo). After a mean loading period of 4.0 +/- 0.5 years (range 3.2 to 4.8 y), 56 implants remained in place. This study confirms Bio-Oss's good osteoconductive properties.