PubMed · 2007 · 111 citations · 19 references
DentistryImplant DentistryProsthodonticsImplant ProsthodonticsImplant SurgeryProstheticsComputer-aided Design In ProsthodonticsImplant DesignCnc MillingContact Coordinate MeasurementImplant Framework DesignMillingTitanium Framework Fabrication
PURPOSE: To compare the in vitro 3-dimensional (3D) accuracy of fit of laser-scanned Computer Numeric Controlled (CNC)-milled implant titanium frameworks to that of conventional cast frameworks. MATERIALS AND METHODS: Nine cast frameworks were fabricated on the mandibular master casts of 9 patients with 5 implants each following the well-established conventional fabrication technique. The frameworks were then laser scanned, and 9 CNC-milled titanium frameworks matching the outline of the conventional frameworks were fabricated. The accuracy of fit of both framework types was measured using a contact-type coordinate measuring machine and a computer program developed specifically for this purpose. Statistical analysis was done by a series of paired ttests. RESULTS: The laser-scanned CNC-milled frameworks showed significantly less distortion along the x-axis (transversal, d(x)) compared with the conventional frameworks (means: 33.7 microm and 49.2 microm, respectively) (P = .011). The titanium frameworks also demonstrated significantly less distortion on the horizontal plane compared with the conventional frameworks (means: 56 microm and 85 microm, respectively) (P = .012). The d(y) (sagittal) and d(z) (vertical) axes and total 3D distortion (square root of dx(2) + dy(2) + dz(2)) showed less distortion overall in the laser-scanned CNC-milled frameworks, but this was not statistically significant (mean: 22.3 vs 35.6 microm, 13.3 vs 59.2 microm, 51 vs 114.1 microm, respectively, for y, z, and 3D distortion). CONCLUSION: Within the limitations of this study, fabrication of an implant-prosthodontic framework using the CNC milling technique yields a more accurate fit than the currently used cast technique. In vivo studies are needed to investigate the clinical significance of this recorded difference.
19
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
R Adell, U. Breine, Johan Lindström et al. · PubMed · 1977 · 2.4K citations
Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.
R Adell, Bengt O. Eriksson, Ulf Lekholm et al. · PubMed · 1990 · 1.9K citations
Biomechanical considerations in osseointegrated prostheses
Richard Skalak · Journal of Prosthetic Dentistry · 1983 · 756 citations