American Journal of Physiology-Legacy Content · 1961 · 37 citations · 0 references
PharmacyNephrologyPharmacokineticsDrug ClearanceRenal PathophysiologyRenal PharmacokineticsRenal ClearanceRenal Drug ClearanceChromium KineticsChromium RetentionChromium TransportEquilibrium DialysisRenal Excretion RateRenal Mineral ExcretionTubular Reabsorption KineticsUrinary Chromium Excretion
Renal clearance of chromium decreases exponentially with time after a single intravenous injection of Cr 51 Cl 3 from 2.5 or 3 ml/min/m 2 at 1 hr to less than 1 ml/min 8 hr post-injection. Equilibrium dialysis measurements showed similar results for plasma dialyzable chromium. These observations lead to the determination of a dialyzable chromium clearance (C d-cr ) in which the concentration in dialyzable chromium replaced total plasma chromium in the clearance formula. The mean and standard deviation for C d-cr of 36.6 ± 11.6 ml/min/m 2 was relatively unaffected by time after chromium administration, plasma concentration of dialyzable chromium, or rate of urine flow. Values of C d-cr determined repeatedly in two dogs intravenously infused with Cr 51 Cl 3 for over 7 hr also remained stable. Glomerular filtration and tubular reabsorption are involved in renal excretion of chromium. The lack of a reduction of C d-cr at high plasma levels of dialyzable chromium favors the conclusion that tubular excretion is of minor importance. Simultaneous creatinine and PAH clearances were normal, indicating that renal function was not impaired by the doses of chromium used.